Monitoring a heritage hotel in the historic centre of Cologne

Case Study

在翻新期间监视历史悠久的Dom Carre酒店

作者:史蒂文·瑟古德(Steven Thurgood)

In the ancient city of Cologne, the Dom Hotel is one of the oldest Grand Hotels in Europe. It first opened in 1857, underwent its first renovation in the 1800s, another after the Second World War and has been in a process of modernisation since 2014. Germany’s Cultural Heritage Policy ensures the preservation of historic buildings and culturally significant structures, meaning that the 5-star hotel’S原始FA必须保留Çade和楼梯。施工运营始于2016年,部分拆除内部结构于2019年达成协议。

Surveying engineering specialist,Vermessungsbürokds该项目被任命为在建设过程中对遗产建筑进行结构监测。遵循拆除的设计风险评估,计算了遗产外墙的变形和运动的结构矩公差ade. Martin Reck of Vermessungsbüro KDS worked with Leica Geosystems’regional monitoring solutions expert, Heiner Gilleßen, to design a plan for monitoring the sensitive structure.

在翻新期间监视历史悠久的Dom Carre酒店


Deploying solutions built for sensitivity

Leica Geosystems通常建议部署Leica Nova TM60andGeoMoS Edgesolution to measure prisms on the hotel’s structure, but the support frame on the façade and its coverings meant that there was no line of sight for an optical system. Instead Gilleßen suggested a mix of solutions from the wider Hexagon Geosystems, Leica Geosystems and third-party portfolio that he could integrate into theGeoMoS Monitoring Solution。该套件可以灵活地和速度理解和对监视项目中的复杂需求做出反应。

由于需要监视立面的规范,但没有用于光学设备的物理访问或视线,HeinerGilleßen建议使用无线倾斜传感器,这些传感器可以快速轻松地安装,同时几乎不需要维护。来自传感器的所有数据仍然可以管理和可视化Leica GeoMoS Now!- 一个基于Web的应用程序,可为授权人员查看数据提供简单但安全的访问权限。这种工具的组合使客户无需学习或实施新的软件套件就可以添加系统。

总共将18个传感器安装在立面上的各个位置,从而使精确的自动监视完成,以拆除内部酒店结构的拆除,以旋转立面。其中包括15个两轴倾斜传感器,一个门户和太阳能电池板。还将距离传感器与基本倾斜传感器结合使用,以测量结构壁的偏移,并确保结构的几何形状保持恒定。这尤其重要,因为酒店的电梯轴将不受该项目的建筑团队的影响。持续的偏移和倾斜读数使电梯轴的安全监视。

在翻新期间监视历史悠久的Dom Carre酒店

Generating data-driven results using automation

Since its installation in September 2019, the Leica solution conducts18每30分钟阅读,产生approximately 550,000 data records with an extra 1,000 readings per day. This was available in GeoMoS within 120 seconds of data measurement on-site and made available on the cloud platform of GeoMoS Now!, providing live data around the clock.

When the works programme was extended due to archaeological finds in the basement excavation, the extension of the monitoring scheme’s life was not a problem. The equipment installed is designed to last maintenance-free for years due to 30-minute data acquisition intervals, self-powered internal batteries and IP65 rated enclosures for all-weather working. Gilleßen provided local and remote training for those new to the scheme.

在翻新期间监视历史悠久的Dom Carre酒店

保护Dom Hotel的遗产

Martin Reck and the Vermessungsbüro KDS wider team were very satisfied with the solution provided. In fact, they also utilised a selection of surveying solutions for manual surveying works throughout the project, including theLeica Sprinter 150 Digital level, Leica DNA03, Leica LS15,Leica Disto,Leica Viva GS12 GNSS,Leica Viva GS16 GNSS,Leica TS15和TS16总站andLeica Viva CS10现场控制器

Automation was essential in ensuring the façade was able to remain in the Dom Hotel. With 120 guest rooms and suites on the way for Cologne’s visitors to enjoy, Leica Geosystems played a significant role in protecting the hotel’s rich heritage. As cities evolve and structures develop, tools such as theGeoMoS Monitoring SolutionandLeica GeoMoS Now!are ensuring structural safety and the preservation of history.


Interested in monitoring? Please feel free to read further case studies, showing how our customers use our solution to improve their monitoring workflow:

Monitoring Case Studies

Contact us about Monitoring

与我们联系以获取有关我们监视解决方案的更多信息。